Home>Verify a certificate>Direct Peptides>Certificate 12409

Certificate of analysis

Certificate 12409

AOD9604 5 mg. Purity, identity and net content, released Mar 3, 2026. Issued for Direct Peptides.

Mar 3, 2026Released
Purity, identity and net contentTest
UHPLC-MSMethod
SYN-AOD5-0002Lot

This is the lab's own record. The page is served by BioRegen from the certificate it released, so the figures here and the PDF at the foot of the page are the originals, not a copy held by anyone else.

Results as measured

Read from the certificate the lab released. Each value describes the sample and lot tested, not any other lot.

CompoundIdentity foundPurityNet contentDeclared
AOD 9604Lot SYN-AOD5-0002 · CAS 221231-10-3 · C78H123N23O23S2 · 1815.1 g/mol · White lyophilized powderAOD 960499.84%6.4 mg5 mg

Report details

Method: UHPLC-MS. Identity is the compound found by mass; purity is the main peak as a percentage of all peaks detected; net content is the measured amount in the vial, next to the amount declared at submission.

LC-MS chromatogram

Retention time 2.84 min. Hover or tap the trace to read values.

02550751002.62.83.03.2Time (min)Relative abundance (%)2.84 min
Data table
CompoundRetention timeRecorded window
AOD 96042.84 min2.47 to 3.21 min

Full scan mass spectrum

Scan at the peak, m/z 477 to 1022.

02550751005006007008009001000m/zRelative abundance (%)605.6295907.9392
Data table
m/zRelative abundance
605.6295100.0%
907.939225.5%

Calibration

External standards behind the net content figure, with the instrument's own fit where the certificate prints it.

AOD 9604

R² 0.9884 · 5 standards · equal weighting

02×10⁸4×10⁸035810Standard concentrationPeak area
Data table
StandardConcentrationPeak area
10.9946.75×10⁷
22.511.60×10⁸
35.0362.95×10⁸
47.5454.04×10⁸
510.0714.88×10⁸

The charts are redrawn from the instrument's chromatogram, mass spectrum and calibration data on the certificate. Labeled m/z values are the instrument's own; other positions are read from the plot. Noise filter: chromatogram side peaks under 5% of the main peak are drawn flat; spectrum lines under 10% are left off (the base peak always stays). The PDF is the record.

Certificate PDF

The certificate as the lab released it. PDF · 2 pages · 354 KB

Download PDF

More from the lab

Testing services

UHPLC-MS identity and purity from $165 per sample, LAL endotoxin and pH, results in 2 to 5 business days, every result on a certificate that verifies here.

Submit samples

For research use only. A certificate describes the sample and lot tested, not any other lot. BioRegen is an independent analytical laboratory and does not sell, source or formulate the compounds it tests.