What independent testing can and cannot tell you

Table of Contents

Sign-up Now

To receive updates and offers
Analyst at a microscope in a laboratory, graded in BioRegen green

Independent testing answers specific questions about a specific sample, and answers them well. It does not answer every question. Knowing where the edges are is what makes a certificate useful rather than merely reassuring.

Key points

  • A certificate describes one sample from one lot, as received by the lab.
  • Each result answers one question. Purity, identity, net content and endotoxin are separate tests.
  • Results describe what the method detects. Anything outside its reach is not covered.
  • A certificate reports measurements. It makes no claim about how any compound may be used.

A certificate can tell you

  • Whether the compound named at submission was found, by mass and retention time
  • How much of the detected signal comes from that compound, to two decimals
  • How many mg of it the vial held, when net content is ordered
  • Endotoxin in EU/mL and EU/mg, or that none was detected, when ordered
  • That the record is genuine, through verification

It cannot tell you

  • Anything about a different lot, or another vial that was not tested
  • What happened to the material before or after it reached the lab
  • Results for tests that were not ordered
  • Components the method cannot detect
  • Whether a compound is suitable for any particular use

One sample, one lot

The lab tests what it receives. A certificate speaks for that sample, and for the lot it came from only as far as the sample represents it. A second lot is a second question. Storage, handling and time after testing are outside what any certificate can see.

Each result answers one question

Purity says how clean the main peak is. Identity says whether that peak is the compound named. Net content says how much of it is in the vial. Endotoxin says whether bacterial endotoxin was detected. None of these stands in for another: a sample can show high purity for the wrong compound, or the right compound at half the labeled amount.

From the lab’s data

Across 1,078 pooled results, the expected mass was not found for 38, and the median vial held 106.0% of its labeled amount. See the full data report.

A method sees what it can detect

Purity by UHPLC-MS is the main peak as a share of all peaks detected. Material that does not elute from the column, or does not ionize, adds nothing to the total, so it does not lower the figure. Water and counterions in a powder are not measured as impurities. Compounds with identical masses may need separation by retention time to be told apart. These are properties of the method, and they are why the method is printed on every certificate.

Tests not ordered are not covered

A purity and identity certificate makes no statement about endotoxin, net content or pH. If a question matters, it needs its own test and its own result on a certificate.

Using certificates well

  • Match the lot

    Confirm the certificate’s lot against the material you hold.

  • Read every result, not the headline

    Check identity before purity, and net content if quantity matters.

  • Look for the method

    Results are only comparable when the method is the same.

  • Verify the record

    Check the number and key at bioregen.com/report.

  • Test again when the lot changes

    A new lot needs its own certificate.

Questions

Does a high purity figure mean the vial holds what the label says?

No. Purity describes the composition of what was detected, not the amount. Net content is the measurement for amount.

Can one certificate cover a whole product line?

No. It covers the sample and lot tested. Each lot is a separate question.

Does a certificate say a compound is fit for a purpose?

No. BioRegen certificates report analytical results. They make no statement about the use of any compound, and BioRegen tests for research use only.

For research use only. BioRegen certificates report analytical results for the sample tested and make no claim about the use of any compound.

Share this Article

Related reading

Sample BioRegen certificate of analysis for BPC-157 on a green background
A section by section walk through a purity, identity and net content certificate, with an annotated sample.
Report verification block of a sample BioRegen certificate with key and QR code
Where to find the number and key on a certificate, how to open the lab record, and what to compare.
Analyst at a microscope beside a monitor in a laboratory
Eight questions to ask before sending a sample, and where to find each answer on a certificate.