Research peptide purity: what over 1,000 certificates show

Table of Contents

Sign-up Now

To receive updates and offers
Laboratory bench with a laptop, glassware and microscope

Every certificate BioRegen issues lands in one database. This report pools all of them, across every client, into one view of what submitted research peptide samples actually measure. The figures update on their own as new certificates are published.

Key points

  • Median purity is 99.57% across 1,049 results, and 98% of results are at or above 99.00%.
  • Identity by mass was confirmed for 96% of results.
  • Net content runs high: the median vial holds 106.0% of its labeled amount.
  • 99% of endotoxin reports were below the lowest reportable level of the assay.
1,232certificatesPurity and identity certificates issued since June 2026.
99.57%median purityAcross 1,049 results for the 26 most tested compounds.
96%identity confirmed1,040 of 1,078 results matched the expected mass.
99%endotoxin below limit171 of 173 LAL reports below the lowest reportable level.

What is in the data

Since June 29, 2026, the lab has issued 1,232 purity and identity certificates, along with 173 endotoxin reports and 5 pH reports. Every published certificate is counted, whatever the result.

Purity, identity and net content are pooled over the 26 compounds with at least 10 certificates, 1,078 results in all. Their names are normalized (TB-500 and Thymosin Beta 4 count as one compound, for example), so each result is matched against the right specification. Blends and rarely tested compounds count toward the certificate total but not toward the medians.

Certificates issued per month

Certificates issued per month
June 202637
July 2026317
August 2026203
September 2026349
October 2026219
November 2026107
Purity and identity certificates. Lighter columns are part months: the first month of the record and the month to date.

Purity

Purity is the main peak as a percentage of all peaks detected by UHPLC-MS, printed to two decimals. Across the pooled results the median is 99.57%, and the middle 80% of results fall between 99.34% and 99.81%.

  • 99.00% or higher1,02998%
  • 98.00 to 98.99%5<1%
  • 95.00 to 97.99%6<1%
  • Below 95.00%9<1%
Purity by UHPLC-MS, 1,049 results.

Results below 95% are uncommon: 9 of 1,049. A lower value means more of the detected signal came from components other than the main compound.

Purity is not identity

A sample can print a high purity for the wrong compound. Purity describes how clean the main peak is; identity says whether that peak is the compound named at submission. Both are reported, separately, on every certificate.

Identity

Identity is confirmed when the measured mass and retention time match the specification given at submission. Across the pooled results, 96% matched. For the other 38, the expected mass was not found in the sample. Some of these were submitted under one name and contained another compound; the certificate reports what was measured either way.

Net content

When net content is ordered, the lab measures how much compound is in the vial and compares it with the labeled amount. The median vial holds 106.0% of its label, and the middle 80% fall between 93.3% and 117.9%.

  • More than 10% under label344%
  • Within 10% of label50661%
  • More than 10% over label29135%
Net content measured against the labeled amount, 831 results.

35% of vials hold more than 110% of the label and 4% hold less than 90%. Purity says nothing about the amount in the vial; net content is the measurement that does.

Endotoxin

Endotoxin is tested separately by kinetic chromogenic LAL and reported in EU/mL. Of 173 endotoxin reports, 171 (99%) were below the lowest reportable level of the assay. See endotoxin testing for the method and price.

By compound

Every compound with at least 10 certificates, by number of certificates. Each name opens the compound’s page with its full pooled results, specification and price.

CompoundCertificatesMedian purityIdentity confirmedNet content, median
Retatrutide18599.54%98%103.5%
BPC-15711799.65%99%111.4%
TB-5009999.48%89%103.2%
GHK-Cu8199.54%100%105.3%
Tirzepatide6099.60%100%104.3%
Tesamorelin5599.56%96%110.6%
KPV5499.56%89%104.0%
Ipamorelin4599.55%100%109.8%
MOTS-c4599.61%93%105.7%
Semax4499.53%98%106.3%
CJC-1295 (no DAC)3399.58%100%104.6%
Selank3399.54%94%108.0%
Kisspeptin-102599.65%100%98.8%
PT-1412499.65%96%95.6%
SS-312399.70%96%105.6%
NAD+1999.52%95%96.1%
AOD-96041799.63%100%114.3%
Oxytocin1799.50%100%105.6%
Sermorelin1799.48%100%109.5%
Cagrilintide1399.65%100%104.0%
Melanotan II1399.60%77%105.9%
Semaglutide1399.50%100%106.9%
5-Amino-1MQ1299.36%92%113.1%
Thymosin Alpha-11299.62%92%113.4%
DSIP1199.70%100%112.6%
Epithalon1199.52%100%112.7%

How to read these figures

  • Pooled, not per lot. The figures describe the certificate base as a whole. They say nothing about any single lot; each certificate speaks only for the lot it names.
  • Everything counts. Every published certificate is included, high results and low. Clients and vendors do not choose what is counted.
  • Submitted samples. The figures describe what clients send to the lab, not the market as a whole.
  • Always current. Figures refresh twice a day from the certificate database; the date at the top shows the latest refresh.

Questions

How often do these figures change?

They refresh twice a day from the certificate database, so the counts and medians move as new certificates are published.

Can I see the certificate behind a figure?

Pooled figures are not linked to individual certificates. Any single BioRegen certificate can be checked on the verify page with its number and validation key.

Why is a compound missing from the table?

A compound joins the table once it has at least 10 certificates. Below that, a median would say too little to be useful.

Does a high median apply to a specific lot?

No. The median describes the pooled certificates. A specific lot is described only by its own certificate.

For research use only. These figures summarize analytical results printed on BioRegen certificates. They are not specifications and make no claim about the use of any compound.

Share this Article

Related reading

Analyst measuring a solution into a flask
How much compound vials actually hold against their labels, pooled from every net content result.
Sample BioRegen certificate of analysis for BPC-157 on a green background
A section by section walk through a purity, identity and net content certificate, with an annotated sample.
Report verification block of a sample BioRegen certificate with key and QR code
Where to find the number and key on a certificate, how to open the lab record, and what to compare.