A blend puts two or more peptides in one vial, and a certificate for it has to report each one. BioRegen tests a blend in a single UHPLC-MS run and reports every component separately, with its own identity and purity, on one certificate.

Key points

  • Each component is identified by its own mass and retention time, and gets its own purity result.
  • A composite chromatogram overlays every component in fixed colours, with a mass spectrum for each.
  • Common blends can be picked by name when submitting; the request carries the components, which is what the certificate reports.
  • Blends have their own price, from $200.

One run, every component

The components of a blend separate on the column and leave it at different times. The mass spectrometer measures each one, and each is compared with the specification for that compound. The result is one certificate with a row per component: name, CAS number, formula, identity and purity.

Composite chromatogram of a BPC-157 and TB-500 blend with two overlaid peaks in blue and orange
Composite chromatogram from the sample blend certificate: TB-500 at 2.89 minutes, BPC-157 at 3.12. Your company logo is printed across the chart free of charge, as on the sample.

Reading a blend certificate

  • Results table. One row per component, each with its own identity and purity. A blend has no single purity figure.
  • Composite chromatogram. Every component overlaid on one time axis, each in its own colour, labeled with its retention time.
  • Mass spectra. A separate scan for each component, overlaid, showing the mass behind each identity result.
  • Fixed colours. Each compound keeps its colour from one certificate to the next, so blends are easy to compare.

Close peaks

Components that elute close together are still told apart by mass. That is one reason blends are tested by UHPLC-MS rather than by UV detection alone.

Blends you can pick by name

Type a blend’s name in the submission form and its components fill in automatically. The certificate reports the components.

BlendComponents
WolverineBPC-157, TB-500
GLOWGHK-Cu, BPC-157, TB-500
KLOWKPV, GHK-Cu, BPC-157, TB-500
CJC-1295 (no DAC) / IpamorelinCJC-1295 (no DAC), Ipamorelin
CJC-1295 DAC / IpamorelinCJC-1295 DAC, Ipamorelin
Tesamorelin / IpamorelinTesamorelin, Ipamorelin
Sermorelin / IpamorelinSermorelin, Ipamorelin
Semax / SelankSemax, Selank
BPC-157 / KPVBPC-157, KPV
GHK-Cu / KPVGHK-Cu, KPV
Retatrutide / CagrilintideRetatrutide, Cagrilintide
Any other combination can be entered component by component.

What to send

One vial per test, as for a single compound. Enter each component when submitting, or pick the blend by name, and add the declared amount and lot. Net content can be added to a blend; the submission form shows the price before you send anything.

Questions

Is a blend certificate more expensive than a single compound?

Blends have their own price, from $200, set by the number of components. The submission form shows the total.

Why is there no single purity figure for a blend?

Each component is a separate compound with its own result. Combining them into one figure would hide which component is which.

What if a component is missing from the vial?

The certificate reports what was measured for each component named at submission.

Can I submit a blend that is not in the list?

Yes. Enter the components one by one; they are tested and reported as named.

For research use only. The certificate shown is a sample with illustrative data. BioRegen certificates report analytical results for the sample tested and make no claim about the use of any compound.

Share this Article

Related reading

Analyst holding a petri dish in a laboratory, graded in BioRegen green
Endotoxin units, why results start with "<", how dilution sets the reporting level, and EU/mL to EU/mg.
Liquid chromatography mass spectrometry instrument in the BioRegen laboratory
How the two techniques separate and detect, why identity needs mass, and what that means for a purity figure.
Laboratory bench with a laptop, glassware and microscope
Pooled results from every certificate the lab has issued: purity, identity, net content and endotoxin, by compound, updated automatically.